Santej, Ahmedabad, Gujarat, India CE-Marked Transformers for Export
Serving OEMs & Projects Worldwide

Instrument Transformer Manufacturer & Factory in the Barcelona Market

High-Precision Current & Voltage Transformers Engineered to UNE-EN / IEC 61869 Standards for Catalonia’s Advanced Industrial Automation, Renewable Grid Interties, and Heavy Marine Infrastructure.

Industrial Engineering Intelligence • Catalonia Metropolitan Region

Engineered for High-Reliability Power Measurement & Switchgear Protection

As the Greater Barcelona metropolitan area and the industrial corridor of Catalonia undergo unprecedented grid modernization—driven by the Port of Barcelona electrification, massive EV infrastructure rollouts, and renewable interconnections—the demand for precision instrument transformers with proven electromagnetic resilience has reached critical mass.

5,500 m²
Dedicated Production Facility
0.2S / 0.5
Tariff Metering Precision Class
5000 kVA
Max Power Magnetic Capacity
100%
Routine Tested & CE Compliant
Comprehensive Electrical Hardware Portfolio

Featured Power Distribution & Magnetics Solutions

Engineered for integration into MV/LV distribution panels, motor control centers, and distributed generation plants across Barcelona, Martorell, and Tarragona.

167Kva American Single Phase Pad Mounted Transformer
Substation Unit

Factory Supplied 167Kva American Single Phase Pad Mounted Transformer Outdoor Combined Box-type Substation Transformer

Class: Oil-immersed outdoor step-down
Application: Distributed utility loops, industrial park feeders
Explore Specifications
Puremind Hybrid Solar Inverter Air Conditioner
Clean Energy HVAC

Hybrid Solar Inverter Air Conditioner Puremind DC AC Hybrid Air Conditioner Monoblock Solar Powered Air Conditioners

Operation: Direct DC photovoltaic + AC grid assist
Application: Low-carbon commercial facilities, electrical control rooms
Explore Specifications
200A 3 Phase EV Charging EMI Filter
Power Quality

200A 3 Phase 4 Line 250/440VAC Noise EMI Filter for All Kinds of Charging Stations & Electric Vehicle Power CE Certified

Attenuation: Broad-band high insertion loss
Application: EV ultra-fast charging hubs, high-frequency rectification
Explore Specifications
Automotive Air Conditioner Control Switch Panel
Automotive Systems

Automotive Air Conditioner Control Panel Electric Environment AC Switch Panel

Interface: Ruggedized CAN/analog bus interface
Application: Commercial vehicle cabin climate management
Explore Specifications
25MVA 110KV Oil-Immersed Power Transformer
Heavy Utility

3 Phase Large Oil-Immersed Power Transformer 25MVA 110KV/35KV On-Load Regulating Switch SZ11 OEM 50/60Hz High Quality

Regulation: On-Load Tap Changer (OLTC)
Application: Regional transmission substations, heavy metallurgical works
Explore Specifications
MNS Modular Withdrawable Low Voltage Switchgear
Distribution Gear

MNS Modular Withdrawable Low Voltage Switchgear for Industrial Power Distribution with OEM Engineering Support IP30-IP54 Rating

Form Factor: Modular withdrawable drawers
Application: Motor control centers (MCC), refinery process power
Explore Specifications
Custom Industrial Electric Control Panel
Automation System

Custom Industrial Electric Control Panel Factory Direct PLC Automation Electrical Box for Manufacturing Equipment

Architecture: PLC/SCADA integrated logic execution
Application: Automated manufacturing, packaging, processing lines
Explore Specifications
Industrial Wall Mount HMI Operation Control Box
Operator Interface

Custom Wall Mount Aluminum Alloy IP54 HMI Operation Control Box Display Push Button Panel Integrated Keyboard Industrial

Ingress Protection: IP54/NEMA 12 rated enclosure
Application: Machine operator stations, harsh industrial human-machine interfaces
Explore Specifications

Instrument Transformer Engineering in the Iberian Grid Context

In medium-voltage (MV) and low-voltage (LV) electrical architectures across Spain, instrument transformers—comprising Current Transformers (CT) and Voltage/Potential Transformers (VT/PT)—serve as the indispensable sensory organs of the power distribution grid. Their primary role is twofold: converting high currents and potential voltages into standardized, manageable secondary signals (typically 1A or 5A for CTs; 100V, 110V, or 110/√3 V for VTs), and providing galvanic isolation between high-energy transmission feeders and delicate digital relays, energy meters, and SCADA monitoring units.

Procuring instrument transformers specifically tailored for the Barcelona market requires exact alignment with European harmonized norms, predominantly the UNE-EN IEC 61869-1, 61869-2 (for CTs), and 61869-3 (for inductive VTs). Engineering specifications are governed by strict grid-code requirements dictated by transmission system operators (such as Red Eléctrica de España - REE) and regional distribution network operators (notably Endesa Distribución). Achieving optimal electromagnetic performance requires a profound understanding of core saturation dynamics, rated instrument burden, thermal prospective short-circuit current withstand ($I_{th}$), and dynamic ratings ($I_{dyn}$).

Metering Core Accuracy Classes (0.2S & 0.5S)

For revenue billing and tariff metering along Spanish commercial interconnections, extended-range accuracy cores (Class 0.2S) are mandatory. These cores sustain exceptionally low phase displacement and ratio errors down to 1% of nominal current, preventing fiscal drift under fluctuating intermittent loads.

Protective Core Dynamics (5P10, 5P20, Class PX)

Protection cores are calculated to avoid magnetic saturation during asymmetric fault currents. Specifying accurate Accuracy Limit Factors (ALF) and Knee-Point Voltage ($V_k$) calculations ensures distance and differential relays (e.g., ANSI 87T, 50/51) operate instantaneously without false tripping during severe line faults.

Cycloaliphatic Resin & C5 Marine Resistance

Barcelona’s coastal industrial facilities (e.g., Zona Franca, Port Vell) face pervasive saline moisture and industrial particulates. Utilizing vacuum-cast cycloaliphatic epoxy resin encapsulation provides hydrophobic creepage surfaces, guaranteeing zero partial discharge (< 5 pC) up to 36 kV.

Technical Specification Matrix: CT & VT Selection for Switchgear Integration

The following engineering data outline primary configuration standards for instrument transformers integrated into MNS modular switchgear, gas-insulated switchgear (GIS), and outdoor air-insulated substations (AIS) across Catalan industrial zones:

Parameter / Feature Low-Voltage (LV) Instrument CTs Medium-Voltage (MV) Cast Resin CTs Inductive Potential Transformers (VT)
Rated Insulation Level ($U_m$) 0.72 kV to 1.2 kV (AC withstand 3 kV) 12 kV / 17.5 kV / 24 kV / 36 kV Up to 36 kV (BIL 170 kV peak)
Nominal Primary Ratings 50 A up to 5000 A (Busbar / Ring) 10 A to 2500 A (Single / Double ratio) 3.3/√3 kV up to 33/√3 kV
Standard Accuracy Classes 0.5, 0.2, 0.2S (Revenue Billing) 0.2S (Metering) + 5P10 / 5P20 (Protection) 0.2, 0.5 (Measurement) / 3P, 6P (Relay)
Rated Secondary Burden 2.5 VA, 5 VA, 10 VA, 15 VA 5 VA to 30 VA (Matched loop resistance) 10 VA to 100 VA (Thermal limit up to 500VA)
Harmonized Standard UNE-EN IEC 61869-2 / IEC 61439-1 UNE-EN IEC 61869-2 / Endesa GE NNL001 UNE-EN IEC 61869-3 / Endesa GE NNL002
Primary Construction Type Window/Bushing-type, Split-core retrofit Support-type epoxy cast, Post-insulator Single-pole earthed, Double-pole unearthed

Localized Application Scenarios Across Catalonia's Industrial Infrastructure

The manufacturing and deployment of electrical magnetics must respond directly to specific geographical and operating environments. In the Barcelona area, three major economic corridors drive exacting demands for custom instrument transformers and power conversion hardware:

  • Zona Franca & Port of Barcelona Electrification: As part of the *Nexigen* plan, the Port of Barcelona is investing heavily in Onshore Power Supply (OPS) systems to allow berthed container ships and cruise liners to shut down auxiliary diesel generators and plug directly into the local municipal MV grid. Instrument transformers deployed here require specialized Class C4/C5 corrosion protection, custom secondary tapping for variable shore connection frequencies (50 Hz / 60 Hz), and ultra-low phase angle displacement to support dynamic power-synchronization switchgear.
  • Martorell Automotive & Battery Gigafactory Supply Chains: The rapid re-tooling of automotive manufacturing lines toward electric vehicle architectures has created severe power quality challenges. Automated welding robots, high-frequency curing ovens, and high-capacity battery formation cycling inject extreme harmonic distortions (3rd, 5th, 11th, and 13th harmonics). Here, conventional current transformers suffer premature core heating and ratio saturation. Our magnetic designs incorporate low-loss grain-oriented silicon steel (CRGO) and high-attenuation EMI filtering to ensure precise current sensing alongside PLC automation racks.
  • High-Density Fast EV Charging Plazas (Eix Transversal & AP-7 Corridors): Multi-megawatt EV charging hubs require compact, pad-mounted combined substation transformers coupled with precise multi-circuit metering CTs. The transformers must handle non-sinusoidal currents and rapid load step-changes without tripping sensitive residual-current devices (RCDs) or skewing revenue-grade meters.
  • ADIF & FGC Railway Modernization: The metropolitan passenger railway systems (Rodalies de Catalunya and Ferrocarrils de la Generalitat) operate under rigorous traction power demands. Specialized current transformers monitor catenary supply feeders (1.5 kV DC and 25 kV AC interties), requiring exceptional dielectric endurance against repetitive lightning surges and switching transients.

Emerging Grid Trends: The Transition to Digital Substation Architectures (IEC 61850)

The Catalan electrical utility sector is actively pivoting toward digital substation topologies under the strategic framework of the European Green Deal. Key trends shaping product specifications include:

Low-Power Instrument Transformers (LPIT) & Rogowski Coils: Traditional copper-wound iron-core CTs are increasingly complemented by non-conventional Low-Power Instrument Transformers (LPITs) according to IEC 61869-10 and 61869-11. These sensors leverage Rogowski coils and capacitive voltage dividers to output low-voltage analog signals or directly interface with Merging Units (MUs) that stream Sampled Values (SV) across station process buses compliant with IEC 61850-9-2LE. This eliminates safety hazards associated with open-circuited secondary CT terminals while minimizing space requirements within switchgear enclosures.

Integration of Decentralized Solar & Biomethane Plants in Central Catalonia: As agricultural regions around Lleida, Osona, and Bages deploy utility-scale solar photovoltaic arrays and biogas co-generation plants, bidirectional power flow becomes standard. Instrument transformers at grid tie points must maintain symmetrical measurement accuracy under both export and import regimes, necessitating high-stability dual-core units engineered to withstand wide thermal ambient fluctuations without drifting out of calibration.

Enterprise Competence & Factory Capabilities

Why Tier-1 European EPCs Partner with Prima

Combining over 25 years of electrical engineering excellence, our 5,500 m² state-of-the-art facility delivers customized magnetic and automation hardware built to rigorous international criteria.

Inherited Industrial Automation Heritage (Since 1990)

Formed as a core subsidiary of Prima Automation (India) Pvt. Ltd., our engineering DNA originated in manufacturing complex PC, PLC, and SCADA-based control panels, flameproof panels, and safety-critical motor control centers. We understand magnetics from the panel-builder’s perspective.

Comprehensive Testing & Routine Verification Lab

Every single manufactured unit undergoes exhaustive computer-controlled testing before packing: Double Voltage Double Frequency (DVDF) induced overvoltage testing, computerized open-circuit/short-circuit (OC/SC) diagnostics, digital LCR inductance validation, and automated winding resistance tests.

Full CE Conformity & Export Track Record

Designed expressly for global procurement teams and system integrators. Our products carry legitimate CE markings, accompanied by comprehensive factory routine test certificates, material traceability reports, and full adherence to European Low Voltage Directive (LVD) and EMC requirements.

Expansive Production Envelope (50VA to 5000kVA)

From micro control transformers and high-precision current transducers to heavy three-phase power transformers, reactors up to 2500A, and harmonic filters up to 500HP, our integrated 5,500 m² workshop controls vacuum impregnation, core cutting, winding, and assembly under strict ISO standards.

Procurement & Engineering Due Diligence

Frequently Asked Questions for Spanish Buyers

Direct technical answers addressing standards compliance, logistics to Catalonia, and engineering sizing parameters.

Are your instrument transformers compliant with Endesa Distribución and REE technical standards?
Yes. While our primary design foundation is governed by international harmonized standards (UNE-EN IEC 61869-1, 61869-2, and 61869-3), our custom production lines routinely accommodate specific electrical utility requirements matching Endesa specification norms (such as GE NNL00100 for current transformers and GE NNL00200 for voltage transformers). When requesting a quotation, please submit your single-line diagram (SLD) and tender specifications to ensure exact matching of secondary tapping, short-time thermal ratings ($I_{th}$), and physical terminal block arrangements.
How do you guarantee accuracy class calibration for Class 0.2S revenue-metering units?
Every Class 0.2S and Class 0.2 current transformer undergoes testing in our dedicated, computerized current transformer testing panel. We test ratio error and phase displacement across the full operating spectrum specified by IEC 61869-2: 1%, 5%, 20%, 100%, and 120% of rated nominal current, at both 25% and 100% of rated burden. A serialized factory test report certifying these exact measurements accompanies each dispatched transformer.
What lead times and customs logistics apply for deliveries into the Port of Barcelona?
We maintain dedicated export fulfillment channels for European maritime freight. Standard engineering lead times for custom-wound or cast-resin instrument transformers average 3 to 5 weeks from technical drawing sign-off. Ocean freight transit to the Port of Barcelona (Terminal de Catalunya / BEST) typically requires 21 to 26 days. We provide comprehensive export documentation, including EUR.1 / Certificates of Origin, commercial invoices formatted to Spanish Tax Agency (Agencia Tributaria) standards, packing lists, and CE declarations of conformity for streamlined DDP or CIF customs release.
How do we size the correct VA burden for CT secondary wiring runs in large industrial plants?
Under-burdening or over-burdening a CT can shift its operating point outside its guaranteed accuracy class. Total secondary loop burden equals the sum of the connected instruments' internal impedance (meters, protective relays), the contact resistance of terminal blocks, and the two-way lead resistance of the secondary cabling ($R = \rho \cdot 2L / A$). For long runs (e.g., from an MV switchgear bay to a central control room in a chemical plant in Tarragona or Martorell), choosing a 1A secondary instead of a standard 5A secondary reduces line VA losses by a factor of 25 ($P = I^2 R$), allowing smaller cable cross-sections while preserving Class 0.2S accuracy.
Can you build specialized units for high ambient temperature or corrosive maritime atmospheres?
Yes. For maritime and heavy industrial environments along the Mediterranean basin, we cast transformers using premium hydrophobic cycloaliphatic epoxy resin (HCEP) that resists UV degradation, salt spray, and chemical fumes without surface tracking. Our enclosures can be specified up to IP66/NEMA 4X with stainless steel (AISI 316L) hardware, tinned copper primary terminals, and tropicalized insulation systems rated for continuous operation at ambient temperatures up to 55°C.
What technical parameters are required to generate an immediate engineering proposal?
To receive an optimized quotation and dimensional layout drawing, please provide: (1) System nominal voltage and highest system voltage ($U_m$); (2) Rated frequency (50 Hz standard for Spain); (3) Transformation ratio (e.g., 800/5A or dual-ratio 400-800/1A); (4) Number of cores and their individual functions (e.g., Core 1: Metering Class 0.2S, 10VA; Core 2: Protection Class 5P20, 15VA); (5) Short-circuit requirements ($I_{th}$ for 1s or 3s and $I_{dyn}$); (6) Physical mounting style (bushing, DIN rail, support insulator, or window dimensions).

Ready to Engineer Your Electrical Magnetics Infrastructure?

Whether you require custom-wound instrument transformers for a metropolitan substation upgrade, line reactors for VFD motor protection, or modular switchgear for a new industrial facility in Barcelona, our application engineering team is ready to review your single-line schematics.

Inquire Now